Call 08046075215 81% Response Rate

our range

Components for Inert Gas Fire Suppression Systems

Prominent & Leading Manufacturer from Pune, we offer ss cylinder mounting brackets, constant discharge pressure regulator, solenoid fire cylinder valve with atex coil, discharge nozzles, fire cylinder valve (vds/lpcb) and ul approved fire cylinder valve.
SS Cylinder Mounting Brackets

SS Cylinder Mounting Brackets

Price on Request
DesignCustomized
lengthfor 4 or 6 cylinders
Bracket length645 mm for 4 cylinders and 940 mm for 6 cylinders
ApplicationIndustrial
Fits20 Kg / 30 Kg and 50 Kg cylinders
Brackets to secure a double row of cylinders to a wall - used in total flooding fire protection systems.

Advantages:
  • Multiple brackets can be used for more than 6 cylinders
  • Order 1 Bolt Nuts Kit for 4 cylinders and 2 Kits for 6 cylinders

View Complete details

get quote request a call back
Constant Discharge Pressure Regulator

Constant Discharge Pressure Regulator

Price on Request
Outlet connection W 21,8 x 1/14" DIN 477
MediaGas
Gas TypeIG 01, IG 55, IG 100, IG 541
Inlet connection W 21,8 x 1/14" DIN 477
Body material Brass
MaterialBrass/Bronze
Pressure360 bar
Maximum Pressure 360 bar
Inlet Pressure 300 bar
Pressure regulator to create a constant discharge flow in 200/300 bar inert gas fire protection systems. Key advantages:
  • Reduces discharge pressure to a pre-set 60 bar pressure
  • Reduces cost and complexity of installation for total flooding fire protection systems
  • Allows utilization of lower-cost low-pressure piping and venting


Additional Information:

  • Item Code: B08400003

View Complete details

get quote request a call back
Solenoid Fire Cylinder Valve with ATEX COIL

Solenoid Fire Cylinder Valve with ATEX COIL

Price on Request
MediaGas
Valve Size7 mm
Pressure200 Bar
MaterialBrass/Bronze
Fire cylinder valve for 200 bar inert gas cylinders with ATEX-approved solenoid coil for electronic as well as manual actuation in explosive environments.
Key advantages:
  • ATEX-approved solenoid coil
  • Equipped with gauge port

Specifications:

 

Upper Limit Working Pressure200 bar
2900 PSI
Gas TypeIG 01, IG 55, IG 100, IG 541
Orifice Size7 mm0.27559 Inches
Inlet connection25E EN-629-1
Outlet connectionW 21,8 X 1/14" DIN 477
Dip tube connectionM 10 X 0,75
Operating voltage24 DC
Power consumption11,4 Watts
Body materialBrass


Additional Information:

  • Item Code: B04390316

View Complete details

get quote request a call back
Discharge Nozzles

Discharge Nozzles

Rs 1,500  / PieceGet Best Price
Discharge nozzles where you drill the orifice to the required diameter and assemble it yourself — used in total flooding fire protection systems.
Advantages:
  • Easier to stock
  • More economical alternative
  • Available in 4 thread sizes: ½”, ¾”, 1” and 1½”
  • Maximum working pressure: 300 bar
  • Exceptional quality for dependable fire suppression performance when it counts

Specifications:

Upper Limit Working Pressure300 bar4350 PSI
Gas TypeIG 01, IG 55, IG 100, IG 541, CO2 
Body materialBrass


Additional Information:

  • Item Code: B0461

View Complete details

get quote request a call back
Fire Cylinder Valve (VdS/LPCB)

Fire Cylinder Valve (VdS/LPCB)

Price on Request
Size12 mm
ModelB0480
BrandRotarex
VdS LPCB-approved fire cylinder valves for 200/300 bar inert gas fire protection systems. Key advantages:
  • Available in 200 bar or 300 bar versions
  • VdS and LPCB approved for total flooding fire protection systems
  • Equipped with safety relief device and gauge port
  • Works with a wide range of manual, pneumatic and electromagnetic actuators for a fixed fire extinguishing system
  • Also available in UL-approved version

 

Specifications:

 

Gas TypeIG 01, IG 55, IG 100, IG 541
Upper Limit Working Pressure200, 300 bar2900 PSI
Orifice Size12 mm0.47244 Inches
Inlet connection25E EN-629-1
Outlet connectionW 21.8 x 1/14" DIN 477
Dip tube connectionM 16 x 1
Release device connectionM 42 x 1,5
Safety Relief Pressure270, 450
Certification/HomologationUL, VdS, LPCB

View Complete details

get quote request a call back
UL Approved Fire Cylinder Valve

UL Approved Fire Cylinder Valve

Price on Request
Size12 mm
ModelB0480
Fire cylinder valve for 200 or 300 bar UL-approved inert gas fire protection systems. Key advantages:
  • UL-approved valve burst-disc complies with CGA S1.1
  • Available in 200 bar and 300 bar versions
  • 12 mm orifice size
  • Special connections available on request
  • Also available in VdS-approved fire valve and LPCB-approved versions availablefor total flooding fire protection systems

 

Specifications:

 

Suppression AgentInert gas
Upper Limit Working Pressure200, 300 bar2900 PSI
Seat Orifice Size12 mm0.47244 Inches
Inlet connection25E EN-629-1
Outlet connectionW 21,8 x 1/14" DIN 477
Dip tube connectionM 16 x 1
Release device connectionM 42 x 1,5
Body materialBrass
Safety Relief Pressure300, 450

View Complete details

get quote request a call back
Solenoid Valve for 200 Bar Inert Gas Fire Suppression System

Solenoid Valve for 200 Bar Inert Gas Fire Suppression System

Price on Request
MaterialBrass/Bronze
MediaGas
Pressure200Bar
Solenoid activated fire cylinder valve for 200 bar inert gas fire protection systems. Key advantages:
  • Used as a pilot cylinder for liquid-based fire suppression systems or smaller installations using a single cylinder
  • Solenoid valve for electronic as well as manual actuation
  • Equipped with safety valve and gauge port
  • 270 bar burst-disc pressure
  • For total flooding fire protection systems

Specifications:

 

Upper Limit Working Pressure200 bar2900 PSI
Gas TypeIG 01, IG 55, IG 100, IG 541
Orifice Size7 mm0.27559 Inches
Inlet connection25E EN-629-1
Outlet connectionW 21,8 X 1/14" DIN 477
Operating voltage24 DC
Power consumption10 Watts
Safety Relief Pressure270
Body materialBrass
Dip tube connectionM10 x 0,75

View Complete details

get quote request a call back
Double Row Manifold

Double Row Manifold

Price on Request
Number of Connections2 to 5 cylinders
Material for ConstructionStainless steel
Pressure100 bar
Single-row manifolds to connect from 2 to 5 cylinders at maximum 100 bar pressure — used in total flooding fire protection systems.

Advantages:
  • For inert gas fire suppression systems
  • For CO2 fire suppression systems
  • Single row configuration – for 2 to 5 cylinders
  • Maximum 100 bar (test pressure 150 bar).
  • Exceptional quality for dependable fire suppression performance when it counts
  • Product Code:B 0580

Specifications:

Upper Limit Working Pressure100 bar bar1450 PSI
Gas TypeIG 01, IG 55, IG 100, IG 541, CO2 
Body materialHot Dip Galvanized Steel 
Inlet connectionRc 1" 
Outlet connectionR 2"

View Complete details

get quote request a call back
Single Row Manifold

Single Row Manifold

Price on Request
Material for ConstructionStainless steel
ColorSilver
ShapeCylinderical
Single-row manifolds to connect from 2 to 5 cylinders at maximum 100 bar pressure — used in total flooding fire protection systems.  

Advantages:
  • For inert gas fire suppression systems
  • For CO2 fire suppression systems
  • Single row configuration – for 2 to 5 cylinders
  • Maximum 100 bar (test pressure 150 bar).
  • Exceptional quality for dependable fire suppression performance when it counts
  • Product Code:B0580

Specifications:

Upper Limit Working Pressure100 bar bar1450 PSI
Gas TypeIG 01, IG 55, IG 100, 1G 541, CO2 
Body materialHot Dip Galvanized Steel 
Inlet connectionRc 1" 
Outlet connectionR 2"

View Complete details

get quote request a call back
Brass Check Valve

Brass Check Valve

Rs 2,500  / PieceGet Best Price
BrandDIG
MaterialBrass/Bronze
MediaAir, Water, Gas
ColorGolden
ConditionNew
FinishingBrass Coated
Check valve to prevent backflow into the cylinder that is required for each hose attachment to the manifold — used in total flooding fire protection systems.

Additional Information:

  • Item Code: B04600008

View Complete details

get quote request a call back
Cylinder Valve Assembly with ATEX-Approved Solenoid Valve

Cylinder Valve Assembly with ATEX-Approved Solenoid Valve

Price on Request
Upper Limit Working Pressure200 bar
Length661 mm
Lower Operating Temperature Limit- 20 Celsius
Upper Operating Temperature Limit60 Celsius
Diameter105 mm
BrandDIG
2.7 L manual or solenoid-actuated fire cylinder valve assembly ATEX approved for inert gas fire protection systems. Key advantages:
  • Improves productivity for building fire protection and room fire protection: cylinder/valves arrive pre-assembled
  • Choice of unfilled or filled options
  • ATEX approved solenoid for explosive environments
  • 2.7 Liter Cylinder is CE compliant - no burst disc
  • Used as a pilot cylinder for liquid based fire suppression systems or for smaller applications using a single cylinder


Additional Information:

  • Item Code: B04397001

View Complete details

get quote request a call back
Cylinder Mounting Brackets

Cylinder Mounting Brackets

Price on Request
BrandDIG
Cross Section204 mm and 267 mm
No. of Cylindersbetween 1-5 in a single row
ApplicationIndustrial
Material for Construction Stainless steel
Wall mounting rail, cylinder clamps and end cap parts to mount cylinders to the wall in a single row configuration — used in total flooding fire protection systems.

Advantages:
  • Galvanized steel components for solid support and a long service lifetime
  • Available in multiple lengths to secure between 1-5 cylinders in a single row
  • Multiple brackets may be used for more than 5 cylinders
  • Exceptional quality for dependable fire suppression performance when it counts


Additional Information:

  • Item Code: 02490

View Complete details

get quote request a call back
UL-Approved Pressure Gauges for Gas Fire Suppression System

UL-Approved Pressure Gauges for Gas Fire Suppression System

Rs 9,500  / PieceGet Best Price
TypePressure Gauges
UsageIndustrial, Commercial , Household
CertificationUL Approved
200 and 300 bar pressure gauges for fixed installation inert gas fire protection systems Key advantages:
  • UL approved components - for use with a UL-approved system
  • Integrated pressure switch – normally open
  • Available in 200 bar or 300 bar versions for total flooding fire protection systems
  • Choice of pressure gauge based on pressure and gas type
  • Radial mounting

 

Specifications:

 

Suppression AgentInert gas, IG 100, IG 55, IG 01, IG 541
Gauge connectionM 10 x 1

View Complete details

get quote request a call back
Pressure Gauge for Inert Gas Fire Suppression System

Pressure Gauge for Inert Gas Fire Suppression System

Rs 8,500  / PieceGet Best Price
BrandRotarex
Model02972
CE-approved pressure gauge to measure and display cylinder pressure to confirm the fire safety system is properly charged and ready.
Key advantages:
  • M10 x 1 connection
  • Available in choice of radial or rear-mounted versions for total flooding fire protection systems
  • Gauge scale: 0-360 bar
  • No integrated pressure switch
  • CE-approved

 

Specifications:

Product Code:Series 02972

Gauge connectionM10 x 1
Gauge Face0-350 bar
Certification/HomologationCE
Suppression AgentInert gas

View Complete details

get quote request a call back
Fire Cylinder Valve Assembly for 200/300 Bar Inert Gas

Fire Cylinder Valve Assembly for 200/300 Bar Inert Gas

Price on Request
UsageIndustrial, Commercial , Household
TypeFire Cylinder Valve Assembly
A complete fire cylinder valve assembly for 200 or 300 bar inert gas fire protection systems Key advantages:
  • Improves productivity for building fire protection and room fire protection: cylinder/valves arrive pre-assembled
  • 80 L cylinders available empty or pre-filled with a range of Inert gases
  • Choice of 200 bar or 300 bar versions
  • Fire suppression system cylinders color-coded with green band


Specifications:

 

Gas TypeIG 01, IG 55, IG 100, IG 541
Upper Limit Working Pressure200, 300 bar2900 PSI
Maximum Pressure300, 450 bar4350 PSI
Diameter267 mm10.51179 Inches
Length1770, 1850 mm69.6849 Inches

 

View Complete details

get quote request a call back
Electromagnetic Actuator with Blocking Device

Electromagnetic Actuator with Blocking Device

Price on Request
BrandRotarex
Usageused in fixed installation fire systems
Electromagnetic release device with blocking device — used in fixed installation fire systems.
Key advantages:
  • Electrically actuates the release for fire extinguishing agents
  • For use with Series B0480, B0481 and B0482 fire cylinder valves
  • Exceptional quality for dependable fire suppression performance when it counts
  • With blocking device to perform maintenance while under pressure
  • VdS and LPCB-approved

 

Inlet connectionM42 x 1,5 
Operating voltage24 DC 
Current consumption0,5 A Amps 
Protection classIP65


Additional Information:

  • Item Code: B0442

View Complete details

get quote request a call back
Bleed and Purge Valve

Bleed and Purge Valve

Price on Request
Model029730040
MaterialBrass
Release device connectionG 1/8"
ColorGolden
To vent overpressure and prevent false fire safety system discharge in the event of a small pressure leak from the cylinders into the pneumatic actuators — used in fixed installation fire systems.

Key advantages:
  • Exceptional quality for dependable fire suppression performance when it counts
  • Long service life for cost-effective fire protection


Additional Information:

  • Item Code: 029730040

View Complete details

get quote request a call back
DN12 Straight Discharge Hose

DN12 Straight Discharge Hose

Price on Request
ColorBlack
Unit Length400 mm
MaterialStainless Steel, Rubber
DN 12 straight hose to connect the fire cylinder valve to the manifold in inert gas fire suppression systems and CO2 fire suppression systems.
Key advantages:
  • Exceptionally durable reinforced synthetic rubber - DIN 12
  • High burst pressure - 1520 bar
  • 130 mm maximum bend radius
  • Straight connection
  • Exceptional quality for dependable fire suppression performance when it counts

 

 

Gas TypeInert Gas, CO2, Clean Agent
Upper Limit Working Pressure380 bar5510 PSI
Lower Operating Temperature Limit-40 Celsius-40 Fahrenheit
Upper Operating Temperature Limit100 Celsius212 Fahrenheit
Body materialOil resistant synthetic rubber
Inlet connectionW 21,8 x 1/14" DIN 477
Outlet connectionG 3/4"
Length400 mm15.748 Inches


Additional Information:

  • Item Code: B06920224

View Complete details

get quote request a call back
Discharge Nozzles

Discharge Nozzles

Rs 4,500  / PieceGet Best Price
Pre-bored and fully assembled discharge nozzles — used in inert gas and CO2 total flooding fire protection systems.
Advantages:
  • For faster and easier installation
  • •Available in 4 thread sizes: ½”, ¾”, 1” and 1½”
  • For use with inert gas and CO2 fire suppression agents
  • Special orifice diameters available upon request
  • Maximum working pressure: 300 bar
  • Product Code:B 0461


Specifications:

Upper Limit Working Pressure300 bar4350 PSI
Gas TypeIG 01, IG 55, IG 100, IG 541, CO2 
Body materialBrass

View Complete details

get quote request a call back
Manual Actuator Used in Fixed Installation Fire Systems

Manual Actuator Used in Fixed Installation Fire Systems

Price on Request
Actuator TypeManual Actuator
Manual release device for B0480, B0481, B0482 — used in fixed installation fire systems. Key advantages:
  • Exceptional quality for dependable fire suppression performance when it counts
  • Long service life for cost-effective fire protection

 

 

Suppression AgentChemical Agent, Carbon Dioxide, Inert Gas
Upper Limit Working Pressure150, 250, 340 bar2175 PSI
Lower Operating Temperature Limit-20 Celsius-4 Fahrenheit
Upper Operating Temperature Limit60 Celsius140 Fahrenheit
Inlet connectionM 42 x 1,5
Outlet connectionG 1/8"
Body materialBrass


Additional Information:

  • Item Code: B04420100

View Complete details

get quote request a call back
Pneumatic Actuator - Single Piston

Pneumatic Actuator - Single Piston

Price on Request
ModelB04420066
Usageused in fixed installation fire systems.
Single-piston pneumatic release device 20 BAR for B0480, B0481, B0482 — used in fixed installation fire systems. Key advantages:
  • Exceptional quality for dependable fire suppression performance when it counts
  • Long service life for cost-effective fire protection
  • 20 bar actuation force

 

 

Suppression AgentChemical Agent, Carbon Dioxide, Inert Gas
Upper Limit Working Pressure150, 250, 340 bar2175 PSI
Lower Operating Temperature Limit-20 Celsius-4 Fahrenheit
Upper Operating Temperature Limit60 Celsius140 Fahrenheit
Inlet connectionM 42 x 1,5
Outlet connectionG 1/8"
Body materialBrass

View Complete details

get quote request a call back
Double Piston Pneumatic Actuator

Double Piston Pneumatic Actuator

Price on Request
BrandRotarex
ModelB04420076
Double-piston pneumatic actuator for B0480, B0481 and B0482 fire cylinder valves — used in fixed installation fire systems. Key advantages:
  • Exceptional quality for dependable fire suppression performance when it counts
  • Long service life for cost-effective fire protection
  • 10 bar actuation force

 

 

Suppression AgentAll
Upper Limit Working Pressure300 bar
Inlet connectionM 42 x 1,5
Outlet connectionG 1/8"
Body materialBrass
Height71 mm2.79527 Inches
Diameter50 mm1.9685 Inches

View Complete details

get quote request a call back
Pressure Safety Valve for Manifolds

Pressure Safety Valve for Manifolds

Price on Request
Pressure66 bar
ColorBlue
MaterialStainless steel
Safety pressure-relief device to prevent manifold over-pressure during discharge — used in total flooding fire protection systems.

Advantages:
  • Spring-loaded design closes after over-pressure is relieved
  • Relief pressure 66 bar at 20° C / 971 psi at 68° F
  • Exceptional quality for dependable fire suppression performance when it counts
  • Long service life for cost-effective fire protection


Specifications:

Upper Limit Working Pressure66 bar bar957 PSI
Gas TypeIG 01, IG 55, IG 100, IG 541 
Inlet connectionG 1/2"


Additional Information:

  • Item Code: 029730037

View Complete details

get quote request a call back
Manifold Mounting Brackets

Manifold Mounting Brackets

Price on Request
Suitable ForLED TV, Projector
MaterialStainless Steel
Size205 mm for single row and 505 mm for double row manifolds
Manifold Mounting Brackets - Used in Total Flooding Gas Fire

System of brackets, clamps and end caps to mount manifolds to the wall — used in total flooding fire protection systems.

Advantages:
  • Galvanized steel components for solid support and a long service lifetime
  • Bracket available in two sizes: 205 mm for single row and 505 mm for double row manifolds
  • Clamps accommodate Ø 2
  • Exceptional quality for dependable fire suppression performance when it counts

View Complete details

get quote request a call back
DN 16 Discharge Hose

DN 16 Discharge Hose

Price on Request
ConditionNew
Hose for 140 L cylinders to connect the fire cylinder valve to the manifold — used in total flooding fire protection systems.
Advantages:
  • DN 16 for 140 L cylinders
  • 180 mm max bending radius
  • 1400 bar burst pressure
  • Exceptional quality for dependable fire suppression performance when it counts

Specifications:

Gas TypeInert Gas, CO2
Upper Limit Working Pressure350 bar5075 PSI
Lower Operating Temperature Limit-40 Celsius-40 Fahrenheit
Upper Operating Temperature Limit100 Celsius212 Fahrenheit
Inlet connectionW 21,8 x 1/14" DIN 477
Outlet connectionG 3/4"
Length400 mm15.748 Inches


Additional Information:

  • Item Code: B06920225

View Complete details

get quote request a call back
Double Piston Pneumatic Actuator

Double Piston Pneumatic Actuator

Price on Request
ModelB04420116
Usageused in fixed installation fire systems
Double-piston manual/pneumatic actuator for B0480, B0481 and B0482 fire cylinder valves — used in fixed installation fire systems Key advantages:
  • To actuate the release of fire extinguishing agents
  • Double piston design for dependable fire suppression performance
  • Manual or Pneumatic actuation
  • <150N / 10 bar actuation force
  • Actuation Force: <150N / 10 bar

 

 

TechnologyDouble Piston
Upper Limit Working Pressure300 bar4350 PSI
Inlet connectionM42 x 1,5
Outlet connectionG 1/8"
Body materialBrass

View Complete details

get quote request a call back
Pressure & Flow Detector Switch

Pressure & Flow Detector Switch

Price on Request
Pressure2 bar
Media TypeGas
ColorWhite
Pressure-activated switch to send a signal when the system is discharging — used in fixed installation fire systems.

Advantages:
  • Actuated at 2 bar pressure
  • Flexible voltage/amp power source
  • Test pressure up to 300 bar
  • Exceptional quality for dependable fire suppression performance when it counts
  • Long service life for cost-effective fire protection
  • Product Code:028250050


Specifications:

Upper Limit Working Pressure200 bar bar2900 PSI
Gas TypeIG 01, IG 55, IG 100, IG 541, CO2, Clean Agent 
Gas TypeIG 01, IG 55, IG 100, IG 541, CO2, Clean Agent 
Inlet connectionG 1/2" 
Operating voltage400 AC / 3A, 24 DC / 10 A 
Protection classIP 65

View Complete details

get quote request a call back
Manifold End Cap

Manifold End Cap

Price on Request
Steel fitting to seal the end of a Firetec B0580 manifold — used in total flooding fire protection systems.
Advantages:
  • Conforms to ISO 49 and EN 10242 standards
  • Red dot confirms testing up to 300 bar
  • 100 bar working pressure
  • Exceptional quality for dependable fire suppression performance when it counts
  • Long service life for cost-effective fire protection
  • Product Code:023400100

Specifications:
Upper Limit Working Pressure100 bar bar1450 PSI
Gas TypeIG 01, IG 55, IG 100, IG 541, CO2 
Body materialHot Dip Galvanized Steel 
Inlet connectionG 2" 
Outlet connectionG 2"

View Complete details

get quote request a call back
Pilot Hoses Actuator  - Used In Fixed Installation Fire Systems

Pilot Hoses Actuator - Used In Fixed Installation Fire Systems

Price on Request
TypePilot Hoses
unit Length400, 500, and 700 mm
Hose to connect a master valve or pneumatic actuator with another pneumatic actuator — used in fixed installation fire systems.

Key advantages:
  • Both ends have a straight fitting
  • 400 bar working pressure
  • Available in 3 lengths: 400, 500, and 700 mm
  • Requires an adapter on each end that must be ordered separately
  • Exceptional quality for dependable fire suppression performance when it counts

 

 

Certification/HomologationVdS
Upper Limit Working Pressure400 bar5800 PSI
Lower Operating Temperature Limit-40 Celsius-40 Fahrenheit
Upper Operating Temperature Limit100 Celsius212 Fahrenheit

View Complete details

get quote request a call back
DN12 Straight Discharge Hose

DN12 Straight Discharge Hose

Price on Request
ConditionNew
DN 12 straight hose to connect the fire cylinder valve to the manifold in inert gas fire suppression systems and CO2 fire suppression systems.

Advantages:
  • Exceptionally durable reinforced synthetic rubber - DIN 12
  • High burst pressure - 1520 bar
  • 130 mm maximum bend radius
  • Straight connection
  • Exceptional quality for dependable fire suppression performance when it counts
  • Product Code:B 06920224

Specifications:

Gas TypeInert Gas, CO2, Clean Agent
Upper Limit Working Pressure380 bar5510 PSI
Lower Operating Temperature Limit-40 Celsius-40 Fahrenheit
Upper Operating Temperature Limit100 Celsius212 Fahrenheit
Body materialOil resistant synthetic rubber
Inlet connectionW 21,8 x 1/14" DIN 477
Outlet connectionG 3/4"
Length400 mm15.748 Inches

    View Complete details

    get quote request a call back
    Manifold Connector

    Manifold Connector

    Price on Request
    BrandDeluxe Industrial
    Steel fitting to connect two Firetec B0580 Manifolds — used in total flooding fire protection systems.

    Advantages:
    • Conforms to ISO 49 and EN 10242 standards
    • Red Dot confirms test pressure up to 300 bar
    • Working Pressure 100 bar
    • Exceptional quality for dependable fire suppression performance when it counts
    • Long service life for cost-effective fire protection

    Specifications:

    Upper Limit Working Pressure100 bar bar1450 PSI
    Gas TypeIG 01, IG 55, IG 100, IG 541, CO2 
    Inlet connectionG 2" 
    Outlet connectionG 2"


    Additional Information:

    • Item Code: 026300500

    View Complete details

    get quote request a call back
    Pneumatic Actuator

    Pneumatic Actuator

    Price on Request
    ModelB04420065
    Usageused in fixed installation fire systems.
    Single-Piston Manual Pneumatic Release Device for B0480, B0481, B0483 — used in fixed installation fire systems. Key advantages:
    • Exceptional quality for dependable fire suppression performance when it counts
    • Long service life for cost-effective fire protection
    • Actuation Force: <150N / 20 bar

     

     

    Suppression AgentChemical Agent, Carbon Dioxide, Inert Gas
    Upper Limit Working Pressure300 bar4350 PSI
    Lower Operating Temperature Limit-20 Celsius-4 Fahrenheit
    Upper Operating Temperature Limit60 Celsius140 Fahrenheit
    Inlet connectionM 42 x 1,5
    Outlet connectionG 1/8"
    Body materialBrass

    View Complete details

    get quote request a call back
    Electromagnetic Actuator

    Electromagnetic Actuator

    Price on Request
    Actuator TypeElectromagnetic Actuator
    Electromagnetic release device for series B0480, B0481, B0482 fire cylinder valves — used in fixed installation fire systems. Key advantages:
    • Exceptional quality for dependable fire suppression performance when it counts
    • Different versions available for VdS or UL-approved systems
    • Long service life for cost-effective fire protection
    • Available with and without LED

     

     

    Suppression AgentChemical Agent, Carbon Dioxide, Inert Gas
    Lower Operating Temperature Limit-20 Celsius-4 Fahrenheit
    Upper Operating Temperature Limit60 Celsius140 Fahrenheit
    Inlet connectionM 42 x 1,5
    Body materialBrass
    Operating voltage24 V DC
    Current consumption0,5, 1 Amps
    Protection classIP 65


    Additional Information:

    • Item Code: SERIES-B0442

    View Complete details

    get quote request a call back
    Directional Valves

    Directional Valves

    Price on Request
    Operating voltage24 AC/DC
    Protection classIP 65
    Upper Limit Working Pressure100 bar
    Valve and actuator assembly to isolate separate fire protection zones from the same cylinder rack — used in total flooding fire protection systems.

    Advantages:
    • Isolates discharge only in the zone where there is a fire
    • Includes valve + bracket + motor
    • Available in carbon steel or stainless steel versions
    • Choice of 5 diameters: 1”, 1.5”, 2”, 2.5” and 3”
    • Actuates discharge either electronically or manually

    Specifications:

    Upper Limit Working Pressure100 bar1450 PSI
    Gas TypeIG 01, IG 55, IG 100, IG 541, CO2 
    Operating voltage24 AC/DC 
    Protection classIP 65


    Additional Information:

    • Item Code: B0551

    View Complete details

    get quote request a call back
    DIN 12 90 Discharge Hose

    DIN 12 90 Discharge Hose

    Price on Request
    ConditionNew
    DN 12 discharge hose to connect the fire cylinder valve to the manifold in fixed installation fire systems.

    Advantages:
    • DN 12 90° Elbow Configuration
    • For inert gas fire suppression systems
    • For Inert Gas, CO2 or Clean Agent Systems
    • For clean agent fire suppression systems
    • Exceptional quality for dependable fire suppression performance when it counts

    Specifications:

    Gas TypeInert Gas, CO2, Clean Agent 
    Upper Limit Working Pressure380 bar5510 PSI
    Lower Operating Temperature Limit-40 Celsius-40 Fahrenheit
    Upper Operating Temperature Limit100 Celsius212 Fahrenheit
    Inlet connectionW 21,8 x 1/14" DIN 477 
    Outlet connectionG 3/4" 
    Length450 mm17.7165 Inches


    Additional Information:

    • Item Code: B06920226

    View Complete details

    get quote request a call back

    EXPLORE MORE CATEGORIES